Brazil

FUJI DRI-CHEM SLIDE

NEW

Using only 10L per slide and with interference filtering technology Fujifilm Dri-chem technology brings biochemical results quickly, easily and with high accuracy.

The content on this page is intended to healthcare professionals and equivalents.

Fujifilm DRI-CHEM SLIDE

Colorimetric method slide
(Enzymes, General chemistry, and Immunology)

This multilayer sheet is composed of dry chemical reagents needed for the reaction and other functional materials. It quantifies enzymes and chemicals using the sample interference filtering method and colorimetric reaction.

Potentiometric method slide
 (Electrolytes)

Each slide comes with an ion-selective film electrode for each of Na, K, and Cl. The slides quantify the electrolytes in the sample by a method of sample interferent filtering and potentiometric reaction;

Colorimetry Slide Composition
[image] DRI-CHEM Slide composition of multilayered film - Spreading layer, Reflection layer, Reaction layer, Transparent support film, and Spectrophotometer
Potentiometry blade composition
[image] Potentiometric method electrolytes slide - electrode terminal, potentiometer, pertition materials, and multilayered film electrode

Biochemical tests - General chemistry

24 slides/box

Colorimetry Slides

Colorimetry tests: Biochemistry, enzymes and immunology.
24 blades/sap + QC card

[photo] Box of BUN-P Ⅲ DRI-CHEM Slides with 2 slides in foil wrapper, 2 slides without packaging (front and back view), and QC card

BUN-P III Urea Nitrogen

[photo] Box of CRE-P Ⅲ DRI-CHEM Slides with 2 slides in foil wrapper, 2 slides without packaging (front and back view), and QC card

CRE-P III - CREATININA

For plasma

[photo] Box of NH3-PⅡ DRI-CHEM Slides with 2 slides in foil wrapper, 2 slides without packaging (front and back view), and QC card

NH3-PⅡ

NH3-PⅡ

For ammonia concentration

For whole blood

[photo] Box of NH3-W Ⅱ DRI-CHEM Slides with 2 slides in foil wrapper, 2 slides without packaging (front and back view), and QC card

NH3-W 

NH3-W Ⅱ

For ammonia concentration

Biochemical tests - Enzymes

24 slides/box

For plasma / serum

[photo] Box of GOT/AST-P Ⅲ DRI-CHEM Slides with 2 slides in foil wrapper, 2 slides without packaging (front and back view), and QC card

GOT/AST-P Ⅲ

[photo] Box of GPT/ALT-P Ⅲ DRI-CHEM Slides with 2 slides in foil wrapper, 2 slides without packaging (front and back view), and QC card

GPT/ALT-P Ⅲ

ALP-P Ⅲ

For alkaline phosphatase activity

AMYL-P Ⅲ

For amylase activity

CHE-P

For cholinesterase activity

CKMB-P

For creatine phosphokinase isozyme MB (CKMB) activity

CPK-P Ⅲ

For creatine phosphokinase activity

GGT-P Ⅲ

For γ-glutamyltransferase activity

GOT/AST-P Ⅲ

For aspartate aminotransferase (glutamic oxalacetic transaminase) activity

GPT/ALT-P Ⅲ

For alanine aminotransferase (glutamic pyruvic transaminase) activity

LAP-P

For leucine aminopeptidase activity

LDH-P Ⅲ

For lactate dehydrogenase activity

LIP-P

For pancreatic lipase activity

Products Potentiometry - Electrolytes

Potentiometry tests: Sodium, Potassium, Chloride

24 Blades/Box + QC Card

RE Reference Fluid 8ml x 6 bottles/box
150μl / Test

[photo] Box of Na-K-Cl DRI-CHEM Slides with 2 slides in foil wrapper, 2 slides without packaging (front and back view), next to box of Reference Fluid RE and bottle of reference fluid

NA-K-CI Blade + RE Reference Fluid

For the execution of the electrolyte test, the ISE mode of potentiometry is used.

This technology measures the potentiometric difference between the sample and the mandatory reference fluid
Both products are pipetted and deposited on the slide automatically

Products Immunology

C-Reactive Protein Colorimetry tests: C-Reactive Protein.
DL Dilution Liquor (CRP) 32ml x 1 bottle/box 350 0 μL/ teSt

*Sample is automatically diluted 21x

CP Calibrator 1ml x 3 levels/box 415 0 μL/ calibration

*Calibration should be performed every batch change of blades or every 3 months

[photo] Box of CRP-SⅢ DRI-CHEM Slides with 2 slides in foil wrapper, 2 slides without packaging (front and back view), and QC card, next to box of Diluent DL (CRP) and bottle of diluent DL

CRP-SⅢ

Calibrator CP (CRP)

[photo] 3 bottles of Calibrator CP (CRP) - CP-1 with blue cap, CP-2 with light green cap, and CP-3 with red cap, next to Calibrator CP (CRP) box

Calibrador CP (CRP)

 

CRP calibration must be performed for each new batch of slides.
To perform the C-reactive protein test, the following are used:

1x CRP blade + 0.35ml DL

To perform the C-reactive protein calibration, the following are used:
6x CRP blade +1ml DL + 415μl/calibrator

One pack panels

Comprehensive S-panel

6 panels/box, 12 slides/panel
TP, ALB, ALP, GLU, TBIL, IP, TCHO, GGT, GPT/ALT, Ca, CRE, BUN

  • * Currently available in limited countries

Small Screening S-panel

12 panels/box, 6 slides/panel
ALP, TBIL, GGT, GPT/ALT, CRE, GOT/AST

  • * Currently available in limited countries