Brazil

DRI-CHEM NX600

A biochemistry analyzer with an integrated, easy-to-operate touchscreen and streamlined workflow

The content on this page is intended to healthcare professionals and equivalents.

Product Movie

Advanced operations in a smaller body.

  1. Large panel, touch-sensitive, easy to operate and with fast measurement time.
  2. Intuitive and simple operation
  3. Streamlined workflow.

Why has Fujifilm's Dri-chem technology been chosen over the past few years?

Fujifilm uses technologies that it has developed in the field of photography. Over the past 4 decades, we have been working to improve ease of use and reduce analyzer size. That's why FUJI DRI-CHEM devices are used in various medical centers, such as outpatient clinics, hospital labs, and medical labs.  In addition, they can be used in situations where the water supply is interrupted due to disasters and in remote regions.

Touch-sensitive LCD panel with intuitive operation

The simple and easy-to-use operation screen provides a fast transition speed of 0.5 seconds or less, allowing for easy operation.

Setup screen
Display of results
Help screen

3-Step easy measurement

Set the slide and the specimen, then press the Start key.
All the processes hereafter are fully automated. 

Improved design supports smooth workflow

The input rack has: 12 pipetting tip positions, 10 dilution cups, support for a bottle of up to 1.5ml for reference fluid and diluent.

More compact

A sliding front cover eliminates the need for a large space above the device to open and close the cover.

Functions

Microsample

Each test needs only 10 μL of sample. (CRP needs 5 μL/test, ISE 50μL/3 tests). Manual pipetting can also be performed when the sample is less.

  • * 50μL are used for the simultaneous measurement of three electrolytes.
High throughput

128 tests can be processed per hour.

No calibration

The stability of the reagents in the slides does not require calibration, and the variability of the batches is adjusted by the QC Card;
The QC Card comes with the slide box and is required only once, during the entire validity period of the batch

  • * CRP: Calibration required
    ISE: Calibration and correction are not required. Uncoupled QC card.
Electrolyte measurement function

With the ISE module, the Fujifilm Dri-chem enables measurement of Sodium, Potassium and Chloride electrolytes on a single slide, delivering the measurement in as little as 1 minute.

Wide range of sample tubes

Minimally interfering with pre-analytical sample handling, the Dri-chem can be operated with Fujifilm tubes (0.5/1.5 mL) or be adapted to the main sample tube models on the market.

Automatic dilution function

Automation of work operations such as pipetting and mixing, etc. The only operation required is the insertion of the dilution ratio.

Biological Risk Reduction

After measurement, the pipetting blades and tips are automatically discarded in the disposal box, minimizing the risk of contamination.

Interfacing

Complies with international standards. Smoothly links with a facility’s host system.

Reliable technology ensures test quality.

The FUJI DRI-CHEM slide reagent has high reliability and stability thanks to cutting-edge chemical technology developed during FUJIFILM's long history in the photographic film manufacturing industry. A lower variation of results between operators, high reproducibility of results and daily accuracy, in addition to excellent correlation, are some notable characteristics.

FUJI DRI-CHEM SLIDE

Two types of slides are provided for different test items.

Enzymes, General chemistry, and Immunology

This multilayer sheet is composed of dry chemical reagents needed for the reaction and other functional materials. It quantifies enzymes and chemicals using a colorimetric method of sample interference filtering and colorimetric reaction.

Electrolytes

Each slide comes with an ion-selective film electrode for each of Na, K, and CI. The slides quantify the electrolytes in the sample by a sample interference filtering method and potentiometric reaction.

Accurate and reliable test results from long-term and field-proven technology & experience

GOT/AST

IFCC standardization method (no PALP) (U/L)

GLU

Hexokinase method (mg/dL)

K

Ion-selective electrode method/
dilution method (mEq/L)

CRP

Latex immunoturbidimetry (mg/dL)

Specifications FUJI DRI-CHEM NX series

  Single-specimen analyzer
 
Series name FUJI DRI-CHEM NX600
Width × depth × height 470(W) × 360(D) × 380(H) mm
Weight 28 kg
Number of measurement cells 13 colorimetric + 1 electrolyte (independent)
Throughput (1) (only colorimetry) 128 tests/hour