A maximum of 20 test slides in the slide cartridge will be automatically processed in a single run. Proceeding sample or test can be set up subsequently without waiting for the previous run to fnish.
Fujifilm has been developing analysis devices that work with dry chemistry for laboratory diagnostics since 1984.It has been the market leader in Japan ever since.
FUJIFILM placed special emphasis in designing a simple, easy-to-use operation screen.
Each test requires 10μL of sample. (CRP: 5μL /test, ISE: 50μL /test, dead volume is necessary using automatic measurement.) If there is less sample, measurement can be done by manual pipetting.
The FUJI DRI-CHEM system uses dry type reagents which are very stable. Calibration is not necessary. Variability in the reagent lots are adjusted using the QC card.
Dilution, a time consuming process, is also automated.
The only operation is to input the dilution ratio.
The analyzer is low maintenance.
It does not require special skills or training to maintain.
DRI-CHEM NX500V analyzer can quickly measure 23 different colorimetric parameters and 3 electrolytes.
It has a 128 tests/hour throughput.
S-Panels are prepacked slides which can be easily mounted in the slide cartridge in just one step. This improves work efficiency and waste reduction.
As soon as the pipetting procedure for the first sample is completed, the slides for the next sample can already be set and the test started.
This minimizes waiting time for your patients.
NX500V can measure lipase activity for canine
The FUJI DRI-CHEM slide reagent has high reliability and stability brought by fine chemical technology cultivated through the long history of Fujifilm.
The high quality of Fujifilm reagents is demonstrated by a comparison with the standard measurement methods.
The NX500V IC has a built-in centrifugal separator.
After setting the whole blood sample and slides and pressing the START button, one has only to wait for the measurement results thereafter. The built-in centrifugal separator can cut the pre-treatment process of whole blood samples.
1 ) IC CUP (Integrated Centrifuge Cup)
The hematocytes, which have higher specific gravity than separating agent, are separated and trapped at the outer side of the separating agent after centrifugation.
Only the plasma passes along the groove and gets accumulated at the bottom of the cup after the separation.
2 ) Straw
Function for efficient mixing of whole blood with heparin and dispensing of sample to the cup.
A special straw comes with the cup.