Sophisticated features. Human comfort.

Sophinity - Functionality

The content on this page is intended to healthcare professionals and equivalents.

FUNCTIONALITY

Positioning support function developed using AI technology

Projection Function (Positioning MAP)

Optional

Skin lines and nipple positions extracted from past images are projected onto the imaging table surface, making it possible to capture images that can be easily compared with past images. To compare the right and left breasts, the image of the opposite side can be inverted and projected onto the table.

To further improve positioning techniques

Positioning Analysis Optional

Supports technicians in improving their imaging skills by using AI technology to analyze positioning from the images taken.

*The extraction of the reference point of the pectoralis major muscle and nipple position for positioning was designed using an AI technique called deep learning. There is no automatic change in performance or accuracy of the system after installation

Compression automatic decompression control (Comfort Comp)

For the aim of reducing pain

This function reduces the compression pressure within the range (± 3 mm) where the thickness of the breast does not change after the completion of normal breast compression and therefore reduces the pain of the examinee. The hysteresis* phenomenon is used to reduce the time that the pressure is at maximum pressure compared to normal compression methods.

Principle of automatic decompression

CEDM 
(Contrast Enhanced Digital Mammography)

 

Acquisition en continu d’une image à basse tension (basse énergie) proche de la mammographie conventionnelle et d’une image à haute tension (haute énergie) avec un filtre Cu, dans une même compresssion. Le logiciel génère une image de soustraction d’énergie automatiquement.

*Lorsqu'un produit de contraste iodé est utilisé.

Intelligent AEC - Adjusts the x-ray dose according to breast type

Flexible for different types of breasts

The position of the mammary gland in the Optional breast is analyzed from pre-shot images taken at a low dose. Only the mammary gland area is used, enabling imaging with appropriate technical factors and dose. Even breast implants, for which it is often difficult to determine the correct manual technique can be automatically imaged by identifying the area of the implant.

Breast Density Assessment function (Density Category) - Option