DR Flat Panel Detector with X-Ray indirect conversion technology, Gadolinium Sulfite Scintillator (GOS), wireless (Wireless) and waterproof with IPX 6 rating. It has an exclusive antibacterial coating, Hydro AG. It allows the acquisition of radiographs of the entire body of the patient in a portrait or landscape format, including patients on stretchers or wheelchairs. Detector useful area: 35 x 43 cm, with a 2836 x 2336 pixel matrix and pixel size of 150 µm. 16 bit grayscale resolution. Image reconstruction time of up to 3 seconds after exposure. 2.6 kg weight, including battery. Supports a maximum load of 300 kg. Allows the use of the detector in wired mode (Wired) in the absence of the battery. Battery charging time of approximately 3 hours. Operation console dedicated to the review of digital X-ray images and operational control of the DR system. It has the services of sending images to the server or the printer in the DICOM 3.0 standard and all the resources available for the processing and manipulation of the image parameters with the following characteristics: 17-inch touch screen monitor (LCD); Local memory of 4GB; Local 500 GB hard drive (HD); Local disk storage (HD) of 4000 images; Dynamic range control (DRC) image processing and multi-frequency processing; recording of DICOM image with a media viewer attachable to the quality control station (CD, DVD, USB, etc.); Backup and restoration of images on external media (CD, DVD, USB); Configuration by the user of the processing parameters by anatomical study region; Image rotation/inversion (from top to bottom or right to left); Density change, sensitivity, contrast and latitude of the images; Display in full screen regardless of the monitor to be used; Magnification of image for viewing; Software collimation of the non-irradiated image area (Electronic Shutter); Cutout of the image in the size and position specified by the user; Insertion of tags and notes in the image; Insertion of free text in the image (Notes); Processing for elimination of grid lines; Free configuration for printing various images in diverse layouts; DICOM Service 3.0, Storage; DICOM Service 3.0 Print; DICOM 3.0 Modality Worklist Management.
DR Flat Panel Detector with X-Ray indirect conversion technology, Gadolinium Sulfite Scintillator (GOS), wireless (Wireless) and waterproof with IPX 6 rating. It has an exclusive antibacterial coating, Hydro AG. It allows the acquisition of radiographs of the entire body of the patient in a portrait or landscape format, including patients on stretchers or wheelchairs. Detector useful area: 43 x 43 cm, with 2836 × 2832 pixel matrix and pixel size of 150 µm. 16-bit grayscale resolution. Image reconstruction time of up to 3 seconds after exposure. Weight 3.2 kg, including battery. Supports a maximum load of 300 kg. Allows the use of the detector in wired mode (Wired) in the absence of the battery. Battery charging time of approximately 3 hours. Operation console dedicated to the review of digital X-ray images and operational control of the DR system. It has the services of sending images to the server or the printer in the DICOM 3.0 standard and all the resources available for the processing and manipulation of the image parameters with the following characteristics: 17-inch touch screen monitor (LCD); Local memory of 4GB; Local 500 GB hard drive (HD); Local disk storage (HD) of 4000 images; Dynamic range control (DRC) image processing and multi-frequency processing; recording of DICOM image with a media viewer attachable to the quality control station (CD, DVD, USB, etc.); Backup and restoration of images on external media (CD, DVD, USB); Configuration by the user of the processing parameters by anatomical study region; Image rotation/inversion (from top to bottom or right to left); Density change, sensitivity, contrast and latitude of the images; Display in full screen regardless of the monitor to be used; Magnification of image for viewing; Software collimation of the non-irradiated image area (Electronic Shutter); Cutout of the image in the size and position specified by the user; Insertion of tags and notes in the image; Insertion of free text in the image (Notes); Processing for elimination of grid lines; Free configuration for printing various images in diverse layouts; DICOM Service 3.0, Storage; DICOM Service 3.0 Print; DICOM 3.0 Modality Worklist Management.
DR flat panel detector with indirect X-ray conversion technology, Cesium Iodide scintillator (CsI), wireless (Wireless) and waterproof with IPX 6 rating. It has an exclusive antibacterial coating, Hydro AG. It allows the acquisition of radiographs of the entire body of the patient in a portrait or landscape format, including patients on stretchers or wheelchairs. Useful detector area: 35 x 43 cm, with a matrix of 2836 x 2336 pixels and a pixel size of 150 µm. 16-bit grayscale resolution. Image reconstruction time of up to 3 seconds after exposure. Weight 2.6 kg, including the battery. Supports a maximum load of 300 kg. Allows the use of the detector in wired mode (Wired) in the absence of the battery. Battery charging time of approximately 3 hours. OOperation console dedicated to the review of digital X-ray images and operational control of the DR system. It has the services of sending images to the server or the printer in the DICOM 3.0 standard and all the resources available for the processing and manipulation of the image parameters with the following characteristics: 17-inch touch screen monitor (LCD); Local memory of 4GB; Local 500 GB hard drive (HD); Local disk storage (HD) of 4000 images; Dynamic range control (DRC) image processing and multi-frequency processing; recording of DICOM image with a media viewer attachable to the quality control station (CD, DVD, USB, etc.); Backup and restoration of images on external media (CD, DVD, USB); Configuration by the user of the processing parameters by anatomical study region; Image rotation/inversion (from top to bottom or right to left); Density change, sensitivity, contrast and latitude of the images; Display in full screen regardless of the monitor to be used; Magnification of image for viewing; Software collimation of the non-irradiated image area (Electronic Shutter); Cutout of the image in the size and position specified by the user; Insertion of tags and notes in the image; Insertion of free text in the image (Notes); Processing for elimination of grid lines; Free configuration for printing various images in diverse layouts; DICOM Service 3.0, Storage; DICOM Service 3.0 Print; DICOM 3.0 Modality Worklist Management.
DR flat panel detector with indirect X-ray conversion technology, Cesium Iodide scintillator (CsI), wireless (Wireless) and waterproof with IPX 6 rating. It has an exclusive antibacterial coating, Hydro AG. It allows the acquisition of radiographs of the entire body of the patient in a portrait or landscape format, including patients on stretchers or wheelchairs. Detector useful area: 43 x 43 cm, with 2836 × 2832 pixel matrix and pixel size of 150 µm. 16-bit grayscale resolution. Image reconstruction time of up to 3 seconds after exposure. Weight 3.2 kg, including the battery. Supports a maximum load of 300 kg. Allows the use of the detector in wired mode (Wired) in the absence of the battery. Battery charging time of approximately 3 hours. Operation console dedicated to the review of digital X-ray images and operational control of the DR system. It has the services of sending images to the server or the printer in the DICOM 3.0 standard and all the resources available for the processing and manipulation of the image parameters with the following characteristics: 17-inch touch screen monitor (LCD); Local memory of 4GB; Local 500 GB hard drive (HD); Local disk storage (HD) of 4000 images; Dynamic range control (DRC) image processing and multi-frequency processing; recording of DICOM image with a media viewer attachable to the quality control station (CD, DVD, USB, etc.); Backup and restoration of images on external media (CD, DVD, USB); Configuration by the user of the processing parameters by anatomical study region; Image rotation/inversion (from top to bottom or right to left); Density change, sensitivity, contrast and latitude of the images; Display in full screen regardless of the monitor to be used; Magnification of image for viewing; Software collimation of the non-irradiated image area (Electronic Shutter); Cutout of the image in the size and position specified by the user; Insertion of tags and notes in the image; Insertion of free text in the image (Notes); Processing for elimination of grid lines; Free configuration for printing various images in diverse layouts; DICOM Service 3.0, Storage; DICOM Service 3.0 Print; DICOM 3.0 Modality Worklist Management.