CR SCANNER: Monocassette system, table, for X-rays
X-ray Image Scanning System, desktop, by phosphor plates, mono, with a resolution of 10 pixels/mm in all sizes of X-ray cassettes. Gray scale resolution 12 bits/pixel. Processing capacity of 47 cassettes/hour in size 35 x 43 cm. Operation console, dedicated to the review of digital X-ray images. It has the services of sending images to the server or the printer in the DICOM 3.0 standard and all the resources available for the processing and manipulation of the image parameters with the following characteristics: 17-inch (LCD) Monitor; 4GB local memory; Local 500 GB hard drive (HD); Local disk storage (HD) of 4000 images; Dynamic range control (DRC) image processing and multi-frequency processing; Image recording in JPEG format DICOM with media viewer attachable to the quality control station (CD, DVD, USB, etc.); Backup and restoration of images on external media (CD, DVD, USB); Configuration by the user of the processing parameters by anatomical study region; Image rotation/inversion (from top to bottom or right to left); Density change, sensitivity, contrast and latitude of the images; Display in full screen regardless of the monitor to be used; Image expansion/reduction for viewing; Software collimation of the non-irradiated image area (Electronic Shutter); Cutout of the image in the size and position specified by the user; Insertion of tags and notes in the image; Processing for elimination of grid lines; Noise reduction algorithms; Measurement and angle ruler; cardiac area measurements; Viewing in cinema mode; Preparation and printing of reports; Free configuration for printing various images in diverse layouts; DICOM Service 3.0, Storage; DICOM Service 3.0, Print; DICOM Service 3.0 Modality Worklist Management.
CR SCANNER: Monocassette system, table, for X-rays and mammography
X-ray and Mammography Image Digitization System, desktop, by phosphor plates, monocassette, with a resolution of 10 pixels/mm in all sizes of X-ray cassettes and 20 pixels/mm for mammography cassettes. Reading at 50 and 100 microns. Gray scale resolution of 12 bits/pixel. Processing capacity of 47 cassettes/hour in size 35 x 43 cm. Operation console, dedicated to the review of digital X-ray and Mammography images. It has the services of sending images to the server or the printer in the DICOM 3.0 standard and all the resources available for the processing and manipulation of the image parameters with the following characteristics: 17-inch touch screen (LCD) Monitor; Local memory of 4GB; Local 500 GB hard drive (HD); Local disk storage (HD) of 4000 images; Dynamic range control (DRC) image processing and multi-frequency processing; recording of DICOM imaging with a media viewer attachable to a quality control station (CD, DVD, USB, etc.); Backup and restoration of images on external media (CD, DVD, USB); Configuration by the user of the processing parameters by anatomical study region; Image rotation/inversion (from top to bottom or right to left); Density change, sensitivity, contrast and latitude of the images; Display in full screen regardless of the monitor to be used; Magnification of image for viewing; Software collimation of the non-irradiated image area (Electronic Shutter); Cutout of the image in the size and position specified by the user; Insertion of tags and notes in the image; Insertion of free text in the image (Notes); Processing for elimination of grid lines; Free configuration for printing various images in diverse layouts; DICOM Service 3.0, Storage; DICOM Service 3.0, Print; DICOM Service 3.0 Modality Worklist Management.
CR SCANNER: Monocassette system for X-ray
System for digitizing X-ray images with a resolution of 10 pixels/mm in all sizes of X-ray cassettes. Processing capacity of 43 cassettes/hour in size 35 x 43 cm. Operation console, dedicated to the review of digital X-ray images. It has the services of sending images to the server or the printer in the DICOM 3.0 standard and all the resources available for the processing and manipulation of the image parameters with the following characteristics: 17-inch touch screen monitor (LCD); Local memory of 4GB; Local 500 GB hard drive (HD); Local disk storage (HD) of 4000 images; Bar code reader for identifying cassettes; Dynamic range control (DRC) image processing and multi-frequency processing; DICOM image recording with a media viewer attachable to quality control station (CD, DVD, USB, etc.); Backup and restoration of images on external media (CD, DVD, USB); Configuration by the user of the processing parameters by anatomical study region; Image rotation/inversion (from top to bottom or right to left); Density change, sensitivity, contrast and latitude of the images; Display in full screen regardless of the monitor to be used; Magnification of image for viewing; Software collimation of the non-irradiated image area (Electronic Shutter); Cutout of the image in the size and position specified by the user; Insertion of tags and notes in the image; Insertion of free text in the image (Notes); Processing for elimination of grid lines; Free configuration for printing various images in diverse layouts; DICOM Service 3.0, Storage; DICOM Service 3.0, Print; DICOM Service 3.0 Modality Worklist Management.
CR SCANNER: Monocassette system for X-rays and mammography.
Digitization System for X-ray Images and Mammography by phosphorus plates, monocassette. The digitization of Conventional Radiology Images with a resolution of 10 pixels/mm in all sizes of X-ray cassettes and 20 pixels/mm in Mammography. Reading at 50 and 100 microns. Processing capacity of 62 cassettes/hour in size 35 x 43 cm. Operation console, dedicated to the review of digital X-ray and Mammography images. It has the services of sending images to the server or the printer in the DICOM 3.0 standard and all the resources available for the processing and manipulation of the image parameters with the following characteristics: 17-inch touch screen (LCD) monitor; Local memory of 4GB; Local 500 GB hard drive (HD); Local disk storage (HD) of 4000 images; Bar code reader for identifying cassettes; Dynamic range control (DRC) image processing and multi-frequency processing; DICOM image recording with a media viewer attachable to the quality control station (CD, DVD, USB, etc.); Backup and restoration of images on external media (CD, DVD, USB); Configuration by the user of the processing parameters by anatomical study region; Image rotation/inversion (from top to bottom or right to left); Density change, sensitivity, contrast and latitude of the images; Display in full screen regardless of the monitor to be used; Magnification of image for viewing; Software collimation of the non-irradiated image area (Electronic Shutter); Cutout of the image in the size and position specified by the user; Insertion of tags and notes in the image; Insertion of free text in the image (Notes); Processing for elimination of grid lines; Free configuration for printing various images in diverse layouts; service required. DICOM Service 3.0, Storage; DICOM Service 3.0, Print; DICOM Service 3.0 Modality Worklist Management.
CR SCANNER: Multicassette system for X-rays and mammography
Digitization System for Mammography and X-Ray images by phosphor plates, multicassette, with 4 cassette entries, resolution of 10 pixels/mm in all sizes of X-ray cassettes. Gray scale resolution 12 bits/pixel. Digitalization of mammography images with a resolution of 20 pixels/mm in cassette sizes 18 x 24 cm and 24 x 30 cm. Processing capacity of 120 cassettes/hour in size 35 x 43; Operation console, dedicated to the review of digital X-ray and Mammography images. It has the services of sending images to the server or the printer in the DICOM 3.0 standard and all the resources available for the processing and manipulation of the image parameters with the following characteristics: 17-inch touch screen (LCD) monitor; Local memory of 4GB; Local 500 GB hard drive (HD); Local disk storage (HD) of 4000 images; Bar code reader for identifying cassettes; Dynamic range control (DRC) image processing and multi-frequency processing; DICOM image recording with a media viewer attachable to the quality control station (CD, DVD, USB, etc.); Backup and restoration of images on external media (CD, DVD, USB); Configuration by the user of the processing parameters by anatomical study region; Image rotation/inversion (from top to bottom or right to left); Density change, sensitivity, contrast and latitude of the images; Display in full screen regardless of the monitor to be used; Magnification of image for viewing; Software collimation of the non-irradiated area (Electronic Shutter); Cutout of the image in the size and position specified by the user; Insertion of tags and notes in the image; Insertion of text in the image (Notes); Processing for elimination of grid lines; Free configuration for printing various images in diverse layouts; service required. DICOM Service 3.0, Storage; DICOM Service 3.0, Print; DICOM Service 3.0 Modality Worklist Management.