Technical Data & Line up
LTO Generation Universal
Cleaning
Cartridge
LTO G4/G4 WORM LTO G5/G5 WORM LTO G6/G6 WORM LTO G7/G7 WORM LTO G8/G8 WORM LTO G9/G9 WORM
Basic Specifications
Native Capacity
(Compressed)
800GB
(1.6TB)
1.5TB
(3.0TB)
2.5TB
(6.25TB)
6TB
(15TB)
12TB
(30TB)
18TB
(45TB)
Max.Transfer Rate*1
(Compressed)
120MB/sec.
(Up to
 240MB/sec.)
140MB/sec.
(Up to
 280MB/sec.)
160MB/sec.
(Up to
 400MB/sec.)
300MB/sec.
(Up to
 750MB/sec.)
360MB/sec.
(Up to
 750MB/sec.)
400MB/sec.
(Up to
 1,000MB/sec.)
Number of Tracks 896 1,280 2,176 3,584 6,656 8,960
Servo Band Timing-based servo
Cartridge Memory 32,786bits
(4,096bytes); Internal EEPROM
65,280bits(8,160bytes); Internal EEPROM 130,816bits(16,352bytes); Internal EEPROM 261,888bits
(32,736bytes); Internal EEPROM
Physical Characteristics
Tape Width 12.65mm
Tape Thickness 8.9μm 6.6μm 6.4μm 6.1μm 5.6μm 5.2μm
Tape Length 319m 820m 846m 960m 1,035m
Cartridge Dimensions
(L x W x H)
102 x 105.4 x 21.5 mm
Recommended Operation Environment
Temperature 10~45℃ 15~25℃
Humidity 10~80%RH 20~50%RH
Max Wet Bulb Temperature / Max Dew Point Temperature 26℃ (Max Wet Bulb Temperature) 22℃ (Max Dew Point Temperature)
Recommended Storage Environment
Temperature 16~35℃(Short Term)/16~25℃(Long Term) 15~25℃
Humidity 20~80%RH(Short Term)/20~50%RH(Long Term) 20~50%RH
Max Wet Bulb Temperature / Max Dew Point Temperature 26℃ (Max Wet Bulb Temperature) 22℃ (Max Dew Point Temperature)
Allowable Operation Environment
Temperature 10~45℃ 15~35℃
Humidity 10~80%RH 20~80%RH
Max Wet Bulb Temperature / Max Dew Point Temperature 26℃ (Max Wet Bulb Temperature) 22℃ (Max Dew Point Temperature)
Allowable Storage Environment
Temperature 16~35℃(Short Term)/16~25℃(Long Term) 15~35℃
Humidity 20~80%RH(Short Term)/20~50%RH(Long Term) 20~80%RH
Max Wet Bulb Temperature / Max Dew Point Temperature 26℃ (Max Wet Bulb Temperature) 22℃ (Max Dew Point Temperature)
  • *1 Depends on the drive interface.
  • * The Universal Cleaning Cartridges are designed for use in all LTO Ultrium 1 through 9 drives.
    Specific revisions of firmware may be required for proper operation.
  • * WORM:WORM(Write Once Read Many)is data cartridge in which information, once written, cannot be modified.
    It is a cost-effective storage capability which ensures data is not overwritten, and to help address compliance regulations.
Media/Drive compatibility

〇:Read/write △:Read only(no writing) ×:No read/write

Media/Drive G9 Drive G8 Drive G7 Drive G6 Drive G5 Drive G4 Drive
LTO G9 × × × × ×
LTO G8 × × × ×
LTO G7 × × × ×
LTO G6 × × × ×
LTO G5 × × ×
LTO G4 × × ×