Czech Republic

FUJI DRI-CHEM SLIDE

NEW

Only one drop of blood applied on a small slide can provide test data in an easy and rapid manner. 

The content on this page is intended to healthcare professionals and equivalents.

Fujifilm DRI-CHEM SLIDE

Colorimetric method slide
(Enzymes, General chemistry, and Immunology)

This multilayered slide is composed of dry chemical ingredients needed for the reaction and other functional materials. It quantifies enzymes and chemicals using colorimetric method.
 

Potentiometric method slide
 (Electrolytes)

Each slide comes with an ion selective film electrode for each of Na, K, and Cl. Slides quantify electrolytes in the sample by a potentiometric method.

Composition of multilayered analytical film
Composition of multilayered film electrode

Biochemical tests - General chemistry

24 slides/box

For plasma / serum

BUN-P Ⅲ

CRE-P Ⅲ

ALB-P Ⅲ

For albumin concentration

BUN-P Ⅲ

For urea-nitrogen concentration 

Ca-P Ⅲ

For calcium concentration 

CRE-P Ⅲ

For creatinine concentration 

DBIL-P Ⅱ

For direct bilirubin concentration 

GLU-P Ⅲ

For glucose concentration 

HDL-C-P Ⅲ D

For high density lipoprotein cholesterol concentration

IP-P

For inorganic phosphorus concentration

Mg-P Ⅲ

For magnesium concentration

TBIL-P Ⅲ

For total bilirubin concentration 

TCHO-P Ⅲ

For total cholesterol concentration

TCO2-P

For total carbon dioxide concentration

  1. Applicable only to the analyzers equipped with a 415 nm filter (DRI-CHEM NX500, NX700 and 7000)
  2. Not applicable to PF function
UA-P Ⅲ

For uric acid concentration

TP-P Ⅲ

For total protein concentration 

For plasma

NH3-PⅡ

NH3-PⅡ

For ammonia concentration

For whole blood

NH3-W 

NH3-W Ⅱ

For ammonia concentration

Biochemical tests - Enzymes

24 slides/box

For plasma / serum

GOT/AST-P Ⅲ

GPT/ALT-P Ⅲ

ALP-P Ⅲ

For alkaline phosphatase activity

AMYL-P Ⅲ

For amylase activity

CHE-P

For cholinesterase activity

CKMB-P

For creatine phosphokinase isozyme MB (CKMB) activity

CPK-P Ⅲ

For creatine phosphokinase activity

GGT-P Ⅲ

For γ-glutamyltransferase activity

GOT/AST-P Ⅲ

For aspartate aminotransferase (glutamic oxalacetic transaminase) activity

GPT/ALT-P Ⅲ

For alanine aminotransferase (glutamic pyruvic transaminase) activity

LAP-P

For leucine aminopeptidase activity

LDH-P Ⅲ

For lactate dehydrogenase activity

LIP-P

For pancreatic lipase activity

Biochemical tests - Electrolytes

For plasma / serum / whole blood

Na-K-Cl

Na-K-Cl

24 slides/box
For Na-K-Cl ions concentrations

Reference Fluid RE

8 mL × 6 bottles/box
The specimen and the Reference Fluid RE are deposited on the sample side and the reference side respectively at the same time

Immunological test

For plasma / serum

CRP-SⅢ

CRP-S Ⅲ

24 slides/box
For C-reactive protein concentration

Diluent DL (CRP)

32 mL × 1 bottle/box
The specimen must be diluted 21 times with Diluent DL (CRP)

Calibrator CP (CRP)

CP(CRP)

CP (CRP)

1ml × 3 levels/box
Calibrator CP (CRP) is required when performing calibration.
Do not remove holders attached to the bottles.

One pack panels

Comprehensive S-panel

6 panels/box, 12 slides/panel
TP, ALB, ALP, GLU, TBIL, IP, TCHO, GGT, GPT/ALT, Ca, CRE, BUN

  • * Currently available in limited countries

Small Screening S-panel

12 panels/box, 6 slides/panel
ALP, TBIL, GGT, GPT/ALT, CRE, GOT/AST

  • * Currently available in limited countries