Switzerland

SupriaTM 128

Supria 128 responds to the paradigm shift in the medical field.

The content on this page is intended to healthcare professionals and equivalents.

Supria 128 provides high quality imaging, with a lower dose

Iterative processing for routine examinations

Iterative Processing, used for dose reduction, requires plenty of calculation, making it difficult to apply it in routine examinations. In Supria 128, the image processing unit has been renewed and the processing speed improved, facilitating the use of Iterative Processing (Intelli IP) in routine examinations.

Optimal settings for each facility

Noise reduction strength can be selected from 7 levels. We provide high-quality images by reducing image noise and artifacts with an appropriate exposure dose according to the facility's operation policy.

Low tube voltage scanning

In general, low tube voltage scanning can be expected to increase CT values and improve low-contrast resolution with iodine contrast agents.The noise increased by low tube voltage imaging can be reduced by Intelli IP,  which also reduces the burden on the patient.

Scan any area of the body with submillimeter (0.625mm) imaging

Equipped with a 0.625mm x 64ch = 40mm high resolution wide detector, submillimeter imaging is possible in a short scanning time on any area of the body.

Minimum slice width 0.625mm

The X-ray detector is separated by a partition. The X-ray utilization efficiency decreases by the thickness of this partition. There is a trade-off between X-ray utilization efficiency and spatial resolution, and the detector is equipped with a minimum slice width of 0.625 mm.

Clinically effective

Since it is possible to take a wide range of scans, it is effective for various examinations such as head, lowered arms, and abdominal multi-phase scanning.

Supria 128 provides comfortable patient care

High pitch scanning not limited to FOV

Our original 3D image reconstruction algorithm CORE method allows scanning with whole specification range of the slices thickness and FOV.

  • * Depends on the specifications of the device

Supria 128 provides high functionality

Helpful function for reducing the burden on the patient

As Supria 128 is equipped with a motion artifact correction, body movement can be compensated even after scanning.Even if the patient is out of the effective field of view, such as a patient with a kyphosis, images can be reconstructed without re-scanning in case it is within the maximum effective field of view.

Motion artifact correction
Full FOV data acquisition

ECG Prospective scanning in synchronization with electrocardiogram

ECG Prospective scanning is a function that scans and achieves image in synchronization with electrocardiographic information. Images achieved by ECG Prospective scanning can be used for calcium scoring analysis*1.

  • *1 A 3D workstation equipped with a calcium scoring analysis is required.